Laboratory · Mortar

Masonry, render and screed mortars hold the building together and protect it. Their class (M5, M10…) is proved on prisms tested in bending and compression.

All three tests are accredited under ISO/IEC 17025 (DPA certificate LT 069).

3accredited tests on this page
ISO/IEC 17025DPA certificate LT 069, valid to 07.06.2029
EN · ISO · ASTMcurrent editions of the referenced standards
In our laboratoryVrrin, Durrës–Tirana motorway, km 29

When you need these tests

  • Verifying the class of site-mixed or factory dry mortar.
  • Producers’ factory production control.
  • Seismic assessment of existing masonry, where mortar strength is an input.

Accredited tests and standards

Mortar tests

Test What it tells you Range Standard Where
Flexural and compressive strength of hardened mortar Mortar class (M5, M10…) from prisms tested in bending and compression 2.5–25 MPa BS EN 1015-11:2019 Laboratory
Dry bulk density of hardened mortar Density of the hardened mortar < 3000 kg/m³ BS EN 1015-10:1999 Laboratory
Particle size distribution Grading of mortar sand and dry mortar < 4.75 mm BS EN 1015-1:1999 Laboratory

Sampling and what to send us

  • Dry mortar: a sealed bag of at least 5 kg.
  • Site mortar: prisms 40×40×160 mm cast in our moulds, or fresh mortar for us to cast.

What your test report contains

  • A unique report number, the accredited laboratory’s details and the ISO/IEC 17025 accreditation mark for accredited tests.
  • Sample identification, sampling details and the condition of the sample on receipt.
  • The standard and method used for every test, with any deviation stated.
  • Results with units, and comparison with the specified limits when you give them to us.
  • Signature of the authorised laboratory staff.

Frequently asked questions

What mortar class do I need?

The designer specifies it; M5 and M10 are common for masonry. Our test confirms whether the mortar delivered reaches it.

Related testing

Need these tests for your project?

Tell us the material, the quantity of samples and the specification you are working to. We’ll confirm the tests, the sampling and the price.

Request a quote